SEP
Combination Metering Provisions & Main(s)
Service Entrance Panel: Xcel Energy
MAIN SEP PANEL
600 VOLT 3 PHASE 4 WIRE
| Amp Rating |
Cat. No |
List Price |
Dimensions |
Weight |
| 400/800 |
SEP8-4(*) |
3600.00 |
? x 36" x 18" |
220# |
MAIN SEP PANEL
600 VOLT 1 PHASE 3 WIRE
| Amp Rating |
Cat. No |
List Price |
Dimensions |
Weight |
| 400/800 |
SEP8-3(*) |
3500.00 |
? x 36" x 18" |
200# |
| X-UNITS AVAILABLE |
|
MOUNTING SPACE REQUIRED FOR MSW AND MCB |
| CABINET WIDTH |
X UNITS |
|
AMP |
2 POLE |
3POLE |
| 24" |
14X |
|
30-200 |
2X |
3X |
| 30" |
18X |
|
400 240V |
4X |
4X |
| 33" |
20X |
|
400 600V |
5X |
5X |
| |
|
|
600 |
6X |
6X |
NOTE: X unit = width of device (each x unit is 1.37" per unit)
FILL IN CATALOG# (*) WITH (B) FOR LINE & CT COMPARTMENT AT BOTTOM
or (T) FOR LINE & CT COMPARTMENT AT TOP.
PULLBOX REQUIRED WHEN LINE AND LOAD CONDUCTORS
ENTER AND EXIT CABINET AT THE SAME END. (SEE TABLE BELOW)
PULL BOX & DIMENSIONS FOR FIELD INSTALLATION
| Amp Rating |
Cat. No |
List Price |
Pull Box Dimensions |
Weight |
| 400/600/800 |
PBMS72 |
600.00 |
72"H x 7"W x 12"D |
72# |
| 1200 |
PB72 |
600.00 |
72"H x 18"W x 10"D |
120# |
MAIN SWITCHES
(INCLUDES FUSES, STANDARD ISC RATING = 200KAIC)
3 Pole (installed)
| Amp Rating / X Units Required |
Volt |
Fuse |
Cat. No |
List Price |
| 30 (3x) |
240 |
R |
PR321N |
306.00 |
| 30 (3x) |
600 |
T |
PT361N |
360.00 |
| 60 (3x) |
240 |
R |
PR322N |
318.00 |
| 60 (3x) |
600 |
T |
PT362N |
360.00 |
| 100 (3x) |
240 |
T |
PT323N |
462.00 |
| 100 (3x) |
600 |
T |
PT363N |
570.00 |
| 200 (3x) |
240 |
T |
PT324N |
612.00 |
| 200 (3x) |
600 |
T |
PT364N |
768.00 |
| 400 (4x) |
240 |
T |
PAT325N |
1404.00 |
| 400 (5x) |
600 |
T |
PAT365N |
1860.00 |
MAIN SWITCHES
(INCLUDES FUSES, STANDARD ISC RATING = 200KAIC)
2 Pole (installed)
| Amp Rating / X Units Required |
Volt |
Fuse |
Cat. No |
List Price |
| 30 (2x) |
240 |
R |
PR221N |
216.00 |
| 30 (2x) |
600 |
T |
PT261N |
258.00 |
| 60 (2x) |
240 |
R |
PR222N |
222.00 |
| 60 (2x) |
600 |
T |
PT262N |
258.00 |
| 100 (2x) |
240 |
T |
PT223N |
330.00 |
| 100 (2x) |
600 |
T |
PT263N |
426.00 |
| 200 (2x) |
240 |
T |
PT224N |
372.00 |
| 200 (2x) |
600 |
T |
PT264N |
570.00 |
| 400 (4x) |
240 |
T |
PAT325-2PN |
1176.00 |
MAIN CIRCUIT BREAKERS (CUTLER HAMMER)
3 Pole (installed)
| Amp Rating / X Units Required |
ISC Rating |
Cat. No |
List Price |
| 240V |
480V |
| 15-60 (3x) |
18KAIC |
14KAIC |
EHD30(+)N |
590.00 |
| 15-60 (3x) |
65KAIC |
35KAIC |
FD30(+)N |
920.00 |
| 15-60 (3x) |
100KAIC |
65KAIC |
HFD30(+)N |
1180.00 |
| 70-100 (3x) |
18KAIC |
14KAIC |
EHD3(+)N |
685.00 |
| 70-100 (3x) |
65KAIC |
35KAIC |
FD3(+)N |
1020.00 |
| 70-100 (3x) |
100KAIC |
65KAIC |
HFD3(+)N |
1405.00 |
| 100-225 (3x) |
65KAIC |
NA |
ED3(+)N |
830.00 |
| 110-225 (3x) |
65KAIC |
35KAIC |
FD3(+)N |
1750.00 |
| 110-225 (3x) |
100KAIC |
65KAIC |
HFD3(+)N |
2375.00 |
| 250-400 (4x) |
65KAIC |
NA |
DK3(+)N |
1790.00 |
| 250-400 (4x) |
65KAIC |
35KAIC |
KD3(+)N |
2825.00 |
| 250-400 (4x) |
100KAIC |
65KAIC |
HKD3(+)N |
4690.00 |
| 450-600 (6x) |
65KAIC |
35KAIC |
LD3(+)N |
4610.00 |
| 450-600 (6x) |
100KAIC |
65KAIC |
HLD3(+)N |
6685.00 |
MAIN CIRCUIT BREAKERS (CUTLER HAMMER)
2 Pole (installed)
| Amp Rating / X Units Required |
ISC Rating |
Cat. No |
List Price |
| 240V |
480V |
| 15-60 (2x) |
18KAIC |
14KAIC |
EHD20(+)N |
485.00 |
| 15-60 (2x) |
65KAIC |
35KAIC |
FD20(+)N |
805.00 |
| 15-60 (2x) |
100KAIC |
65KAIC |
HFD20(+)N |
940.00 |
| 70-100 (2x) |
18KAIC |
14KAIC |
EHD20(+)N |
595.00 |
| 70-100 (2x) |
65KAIC |
35KAIC |
FD2(+)N |
920.00 |
| 70-100 (2x) |
100KAIC |
65KAIC |
HFD2(+)N |
1160.00 |
| 100-225 (2x) |
65KAIC |
NA |
ED2(+)N |
415.00 |
| 110-225 (2x) |
65KAIC |
35KAIC |
FD2(+)N |
1605.00 |
| 110-225 (2x) |
100KAIC |
65KAIC |
HFD2(+)N |
2215.00 |
| 250-400 (4x) |
65KAIC |
NA |
DK2(+)N |
1515.00 |
| 250-400 (4x) |
65KAIC |
35KAIC |
KD2(+)N |
2340.00 |
| 250-400 (4x) |
100KAIC |
65KAIC |
HKD2(+)N |
4235.00 |
| 450-600 (6x) |
65KAIC |
35KAIC |
LD2(+)N |
3670.00 |
| 450-600 (6x) |
100KAIC |
65KAIC |
HLD2(+)N |
5465.00 |
(+) ADD AMPERE RATING T0 CATALOG NUMBER ABOVE.
NOTES:
• ELECTRICAL CONTRACTOR TO EXTENED UTLITY METERING SECONDARY
CONDUIT TO THE CT INTERIOR COMPARTMENT.
• SEP STANDARD LINE CONNECTORS ARE:
400-800 AMP (2) 750KCMIL PER PHASE
AND NEUTRAL.
• CONTACT FACTORY FOR PRICING ON OTHER
BRANDS OF CIRCUIT BREAKERS,
(SIEMENS, SQUARE D & G.E., ETC).